DIP SWITCHES SET UP
Page 24 User’s guide ref 9014709-02 XSLAN SHDSL switch
4 Testing the SHDSL connection and adjusting the data rate
Connect two SHDSL switches to the line and power them up.
Remark :
For test purpose on a desk, the line can be replaced by any Ethernet
straight cable.
The line led of the RJ45 SHDSL connector (it is the lower led) blinks
during the connection phase (45 seconds more or less) and lights on
when the connection is established.
Test the error rate by pinging remotely one of the devices connected to
the other XSLAN.
If the Ping error rate is not close to 0%, modify the setting of the LTU
(XSLAN Nr 1).
Decrease the data rate using the DIP switches SW3, SW4, SW5.